400V AC coil from the CS4 series. Only uses 8VA. Compatible with solenoid valves of the CM series of JP Fluid Control.
Including connectorNotice: This product is discontinued
Description
Specifications
Downloads
Related products
Description
Dimensions
Dimensions of the CS4 coil in mm.
Solenoid valve coil of the JP Fluid Control series (400V AC) including DIN-B connector. Please look at the table below to see which solenoid valves are suitable for this coil.
Valve Series | Function | Orifice | 230VAC | 24VDC | 24VAC | 12VDC | 120VAC |
---|---|---|---|---|---|---|---|
ST-DA / ST-SA / ST-IA | NC | 3 - 50 mm | CS1 | CS1 | CS1 | CS1 | CS1 |
ST-DB | NO | 1 - 4 mm | CS1 | CS1 | CS1 | CS1 | CS1 |
TW-DB / TW-DC / TP | 3/2 NO/DI | 1.5 - 3 mm | CS1 | CS1 | CS1 | CS1 | CS1 |
LP | NO | 6 - 9 mm | CS1 | CS1 | CS1 | CS1 | CS1 |
LP | NO | 19 - 45 mm | CS2 | CS2 | CS2 | CS2 | CS2 |
ST-IB | NO | 13 - 50 mm | CS2 | CS2 | CS2 | CS2 | CS2 |
DF-SA | NC | 16 - 25 mm | CS2 | CS2 | CS2 | CS2 | CS2 |
DF-SA | NC | 32 - 50 mm | CS8 | CS8 | CS8 | CS8 | CS8 |
DF-SB | NO | 16 - 25 mm | CS2 | CS2 | CS2 | CS2 | CS2 |
TW-DA / TW-DD | 3/2 NC/UN | 1.5 - 3 mm | CS3 | CS3 | CS3 | CS3 | CS3 |
HP-DA | NC | 1 - 1.5 mm | CS3 | CS3 | CS3 | CS3 | CS3 |
CM | NC | 2 - 12 mm | CS4 | CS4 | CS4 | CS4 | CS4 |
HP-IA | NC | 8 - 15 mm | CS5 | CS5 | CS5 | ||
PV | NC | 15 - 45 mm | CS6 | CS6 | CS6 | CS6 | CS6 |
PS Type A | 3/2, 5/2, 5/3 | CP1 | CP1 | CP1 | CP1 | CP1 | |
PS Type B/C/D | 3/2, 5/2, 5/3 | CP2 | CP2 | CP2 | CP2 | CP2 |
NC= Normally Closed, NO = Normally Open, DI = diverting, UN = universal
Important
- Please make sure that the type of coil is suitable for the type of solenoid valve.
- Only use the correct power supply as specified on the label. DC voltage applied to an AC voltage coil can lead to damage.
- Never power the coil when it is not mounted on the solenoid valve. The coil will overheat and may burn out.
- The coil is only properly insulated if all components, cables and connectors are properly connected.
- The coil heats up during use. This is normal. Do not touch the coil or valve when it is hot.