CS1 coil DIN-A connector 400V AC
Reference:
CS1-380AC
Brand:
JP Fluid Control
400V AC coil from the CS1 series. Suitable for solenoid valves of a part of the ST, the TW-B/C, the TP and a part of the LP series of JP Fluid Control.
Including connector- Regular price
- €24,14
incl VAT
A VAT (value-added tax) is a goods and service tax that pertains to the European Union (EU). We, Tameson, are required by law to collect VAT for orders within the EU for customers that do not supply us with their VAT number.
- Regular price
- €19,63
excl VAT
Description
Specifications
Downloads
Related products
Description
Dimensions

Dimensions of the CS1 coil in mm.
Solenoid valve coil of the JP Fluid Control series (400V AC) including DIN-A connector. Please look at the table below to see which solenoid valves are suitable for this coil.
| Valve Series | Function | Orifice | 230VAC | 24VDC | 24VAC | 12VDC | 120VAC |
|---|---|---|---|---|---|---|---|
| ST-DA / ST-SA / ST-IA | NC | 3 - 50 mm | CS1 | CS1 | CS1 | CS1 | CS1 |
| ST-DB | NO | 1 - 4 mm | CS1 | CS1 | CS1 | CS1 | CS1 |
| TW-DB / TW-DC / TP | 3/2 NO/DI | 1.5 - 3 mm | CS1 | CS1 | CS1 | CS1 | CS1 |
| LP | NO | 6 - 9 mm | CS1 | CS1 | CS1 | CS1 | CS1 |
| LP | NO | 19 - 45 mm | CS2 | CS2 | CS2 | CS2 | CS2 |
| ST-IB | NO | 13 - 50 mm | CS2 | CS2 | CS2 | CS2 | CS2 |
| DF-SA | NC | 16 - 25 mm | CS2 | CS2 | CS2 | CS2 | CS2 |
| DF-SA | NC | 32 - 50 mm | CS8 | CS8 | CS8 | CS8 | CS8 |
| DF-SB | NO | 16 - 25 mm | CS2 | CS2 | CS2 | CS2 | CS2 |
| TW-DA / TW-DD | 3/2 NC/UN | 1.5 - 3 mm | CS3 | CS3 | CS3 | CS3 | CS3 |
| HP-DA | NC | 1 - 1.5 mm | CS3 | CS3 | CS3 | CS3 | CS3 |
| CM | NC | 2 - 12 mm | CS4 | CS4 | CS4 | CS4 | CS4 |
| HP-IA | NC | 8 - 15 mm | CS5 | CS5 | CS5 | ||
| PV | NC | 15 - 45 mm | CS6 | CS6 | CS6 | CS6 | CS6 |
| PS Type A | 3/2, 5/2, 5/3 | CP1 | CP1 | CP1 | CP1 | CP1 | |
| PS Type B/C/D | 3/2, 5/2, 5/3 | CP2 | CP2 | CP2 | CP2 | CP2 |
NC= Normally Closed, NO = Normally Open, DI = diverting, UN = universal
Important
- Please make sure that the type of coil is suitable for the type of solenoid valve.
- Only use the correct power supply as specified on the label. DC voltage applied to an AC voltage coil can lead to damage.
- Never power the coil when it is not mounted on the solenoid valve. The coil will overheat and may burn out.
- The coil is only properly insulated if all components, cables and connectors are properly connected.
- The coil heats up during use. This is normal. Do not touch the coil or valve when it is hot.