Type of accessory/spare part info

Max pressure (bar) info

Min pressure difference (bar)

Kv value (m3/h) info

Min temperature (°C)

Max temperature (°C)

Degree of protection (IP)

proportional valves & controllers

View Tameson’s selection of proportional solenoid valves and controllers. A proportional solenoid valve allows you to control the flow precisely with a very fast response between 0-100% open, rather than just completely open or closed. Although... Read more Read more

Product Brand Connection size Voltage Material Seal material Function Operation Max pressure (bar) Min pressure difference (bar) Connection type Features Valve bore (mm) Kv value (m3/h) Min temperature (°C) Max temperature (°C) Electrical connection Degree of protection (IP) Nominal power (VA) Duty cycle Max. ambient temp. (°C) Type of accessory/spare part Cablediameter (mm) Nominal current (A) Model Height (mm) Peak power (VA)
G1/2'' Brass 24VDC...
In stock
Burkert 1/2 inch 24 V DC Brass EPDM Normally closed Direct 8 0 Inner thread cylindrical... Proportional control 4 0.45 -30 90 DIN-A IP65 16 100 % 55 - - - - - -
Proportional PWM controller...
+28 days
Burkert - - Polyamide (PA) - - - - - - - - - - - DIN-A - 1 - - Connector 6 mm to 8 mm 2 PG 69 -
Proportional PWM controller...
+28 days
Burkert - - Polyamide (PA) - - - - - - - - - - - DIN-A - 1 - - Connector - 1 Plug-in connection M12 69 -
G3/8'' Brass 24VDC...
+11 days
Burkert 3/8 inch 24 V DC Brass EPDM Normally closed Direct 8 0 Inner thread cylindrical... Proportional control 4 0.45 -30 90 DIN-A IP65 16 100 % 55 - - - - - -
1'' NPT Brass 24VDC...
+11 days
Burkert 1 inch 24 V DC Brass FKM (FPM) Normally closed Indirect 10 0.5 Inner thread conical (NPT) Proportional control 20 5.4 -10 90 DIN-A IP65 16 100 % 55 - - - - - -
G1/2'' Stainless Steel...
+11 days
Burkert 1/2 inch 24 V DC Stainless steel EPDM Normally closed Direct 10 0 Inner thread cylindrical... Fat and oil free,... 8 - - - DIN-A - 16 - - - - - Straight - 16
Proportional PWM controller...
+28 days
Burkert - - Polyamide (PA) - - - - - - - - - - - Screwed terminal - 1 - - Connector - 1 DIN rail (EN50022) 96 -
G3/8'' Brass 24VDC...
+11 days
Burkert 3/8 inch 24 V DC Brass FKM (FPM) Normally closed Indirect 10 0.5 Inner thread cylindrical... Energy efficient (under 9... 10 1.5 -10 90 DIN-A IP65 8 100 % 55 - - - - - -
Proportional PWM controller...
+28 days
Burkert - - Polyamide (PA) - - - - - - - - - - - Screwed terminal - 1 - - Connector - 0.22 DIN rail (EN50022) 96 -
G1/8'' Stainless Steel...
+11 days
Burkert 1/8 inch 24 V DC Stainless steel EPDM Normally closed Direct 8 0 Inner thread cylindrical... Energy efficient (under 9... 0.8 0.018 -30 90 DIN-A IP65 9 100 % 55 - - - - - -
3/8'' NPT Brass 24VDC...
+11 days
Burkert 3/8 inch 24 V DC Brass EPDM Normally closed Direct 25 0 Inner thread conical (NPT) Proportional control 2 0.12 -30 90 DIN-A IP65 16 100 % 55 - - - - - -
G1/4'' Brass 24VDC...
+11 days
Burkert 1/4 inch 24 V DC Brass FKM (FPM) Normally closed Direct 8 0 Inner thread cylindrical... Energy efficient (under 9... 2 0.1 -10 90 DIN-A IP65 9 100 % 55 - - - - - -
SFB Brass 24VDC...
+11 days
Burkert 20x20 mm 24 V DC Brass FKM (FPM) Normally closed Direct 3 0 Flange SFB Energy efficient (under 9... 1.6 0.055 -10 90 DIN-B IP65 5 100 % 55 - - - - - -
1/8'' NPT Brass 24VDC...
+11 days
Burkert 1/8 inch 24 V DC Brass FKM (FPM) Normally closed Direct 5 0 Inner thread conical (NPT) Energy efficient (under 9... 1 0.027 -10 90 DIN-B IP65 5 100 % 55 - - - - - -
G3/8'' Brass 24VDC...
+11 days
Burkert 3/8 inch 24 V DC Brass FKM (FPM) Normally closed Direct 10 0 Inner thread cylindrical... Proportional control 3 0.25 -10 90 DIN-A IP65 16 100 % 55 - - - - - -
proportional valves & controllers

proportional valves & controllers | Tameson

View Tameson’s selection of proportional solenoid valves and controllers. A proportional solenoid valve allows you to control the flow precisely with a very fast response between 0-100% open, rather than just completely open or closed. Although they can be controlled with a simple variable DC signal, it is strongly recommended to use pulse-width modulation (PWM) which limits hysteresis and improves sensitivity. Dedicated PWM controllers for proportional solenoid valves have additional functionalities to improve performance, such as the Bürkert 8605 or 8611. Furthermore, the Bürkert 8605 uses an open loop system and takes an input signal to adjust the valve’s opening to ensure the correct flow parameters (pressure, flow rate, fluid level, temperature, etc.) during operation. Additionally, some controllers can control standard normally open/closed process control valves, sensors, and a wide array of other electrical devices used for fluid control applications. If you need assistance in selecting a valve or controller, please read our article about proportional control valves or contact us.