Rp 1/4'' 2-Way Stainless Steel Electrical Ball Valve 24 V AC/DC
This JP Fluid Control electrical actuator is offered in combination with a TamesonPRO 2-way ball valve. The valve has Rp 1/4'' pipe threads (internal thread, BSPT). The housing and the ball of the valve are made of stainless steel with a PTFE sealing. The actuator is suitable for both 24 volt DC (direct current) and 24 volt AC 50/60Hz (alternating current). With switches on the circuit board, the actuator can be set for AC or DC. The factory default setting is direct current (DC). The actuator has a robust aluminium housing (IP67, provided that an appropriate cable is connected) and delivers maximally 40 Nm torque. The valve rotates from 0 to 90 degrees in 8 seconds. When the ball reaches an end position, the electric motor is turned off and no energy is consumed. The actuator is equipped with two additional limit switches for position-feedback. The limit switches are positioned at 0 and 90 degrees. If required, the angular position of the switches can be adjusted by the user. A mechanical position indicator on the top of the actuator shows the valve position. The actuator is equipped with a manual override.
The valve has a 11.6 mm bore, with Kv value of 8.6 m3/h (Cv = 9.9 gpm). Kv expresses the flow rate of water in m3/h at a pressure drop of one bar. The valve is rated up to 69 bar at 20°C (1000 psi at 68°F). It is suitable for temperatures from -29°C up to 210°C (-20°F up to 410°F). The valve is suitable for water, steam, oil, compressed air, fuels, solvents and aggressive media.- Regular price
- $351.80 USD
We sell only to registered businesses
Description
This JP Fluid Control electrical actuator is offered in combination with a TamesonPRO 2-way ball valve. The valve has Rp 1/4'' pipe threads (internal thread, BSPT). The housing and the ball of the valve are made of stainless steel with a PTFE sealing. The actuator is suitable for both 24 volt DC (direct current) and 24 volt AC 50/60Hz (alternating current). With switches on the circuit board, the actuator can be set for AC or DC. The factory default setting is direct current (DC). The actuator has a robust aluminium housing (IP67, provided that an appropriate cable is connected) and delivers maximally 40 Nm torque. The valve rotates from 0 to 90 degrees in 8 seconds. When the ball reaches an end position, the electric motor is turned off and no energy is consumed. The actuator is equipped with two additional limit switches for position-feedback. The limit switches are positioned at 0 and 90 degrees. If required, the angular position of the switches can be adjusted by the user. A mechanical position indicator on the top of the actuator shows the valve position. The actuator is equipped with a manual override.
The valve has a 11.6 mm bore, with Kv value of 8.6 m3/h (Cv = 9.9 gpm). Kv expresses the flow rate of water in m3/h at a pressure drop of one bar. The valve is rated up to 69 bar at 20°C (1000 psi at 68°F). It is suitable for temperatures from -29°C up to 210°C (-20°F up to 410°F). The valve is suitable for water, steam, oil, compressed air, fuels, solvents and aggressive media.Pros:
- Robust stainless steel ball valve with Rp 1/4'' pipe threads
- Switching time only 8 seconds
- Strong IP67 actuator housing
- Both 24V AC and DC possible (set by switch)
- Two extra limit switches for position feedback
- Manual override control
- Clear visual position indicator
Electrical Wiring Diagram
Follow the safety instructions and manual before you start installation.The actuator works with 24 volt DC and 24 volt AC (50/60Hz). On the PCB are two small switches to set the actuator to AC or DC. The default setting is DC. The actuator draws 0.2A nominal, and 1.2A at maximal torque. The actuator has 3-point control. Terminals 1 (minus) and 2 (plus) are permanently connected to the power supply. Terminals 3 (minus) and 4 (minus) are for the control signals. Connecting one of these control wires, closes or opens the valve. Never connect terminals 3 and 4 at the same time to prevent short circuit and damage. The actuator has two internal limit switches. As soon as the actuator's end position is reached (0 or 90 degrees), the motor turns off and no energy is consumed. In addition, in the actuator there are two additional limit switches for control purposes. The angular position of the limiti switches can be modified. Always connect the earth and do not use the pipes as ground.


Electrical wiring diagram of the AG-040-B actuator. Before using alternating current, first the switches on the PCB need te be set.
Assembly
Make sure that the position of the ball and the actuator are properly set before assembly. The actuator is provided with two adapters to connect the actuator to the valve shaft. Mount the actuator to the valve with the provided bolts. There should be no play between both flanges. Use our fittings range for the connection between the pipe and the valve.
Note: This product is delivered in separate parts, but with the required mounting accessories.