Solenoid Valve RPE 3/8'' Nylon NBR 0.2-10bar 230V AC Food

Notice: This product is discontinued and replaced by V3HH2

Discontinued
Solenoid Valve RPE 3/8'' Nylon NBR 0.2-10bar 230V AC Food
Solenoid Valve RPE 3/8'' Nylon NBR 0.2-10bar 230V AC Food
Solenoid Valve RPE 3/8'' Nylon NBR 0.2-10bar 230V AC Food
Solenoid Valve RPE 3/8'' Nylon NBR 0.2-10bar 230V AC Food
Solenoid Valve RPE 3/8'' Nylon NBR 0.2-10bar 230V AC Food
Solenoid Valve RPE 3/8'' Nylon NBR 0.2-10bar 230V AC Food
Solenoid Valve RPE 3/8'' Nylon NBR 0.2-10bar 230V AC Food
Solenoid Valve RPE 3/8'' Nylon NBR 0.2-10bar 230V AC Food
Solenoid Valve RPE 3/8'' Nylon NBR 0.2-10bar 230V AC Food
Solenoid Valve RPE 3/8'' Nylon NBR 0.2-10bar 230V AC Food
Reference: 4105NC-230VAC
Brand: RPE
Mfr. Part: R Mini 410

Solenoid valve (Brand RPE)with 3/8 inch threads and 230V AC coil. Circuit funtion: Normally closed. Suitable for clean media (max 60°C) with an operating pressure of 0.2-10bar (Indirect operated). Nylon housing with NBR seal. The orifice is 11mm, the Kv-value is 0.95m3/h (15.8 l/min at dP=1 bar, water).

Including coil
View all

Notice: This product is discontinued and replaced by V3HH2

Description
Specifications
Downloads
Related products

indirectly operated valve requires a positive differential pressure of 0.2 bar. For a closed system, such as a cooling unit, a directly operated valve or an electric ball valve is more suitable. The orifice is 11 mm and the Kv-value is 0.95m3/h. The Kv-value is used to chemical resistance chart for other media.

Solenoid valves are electrically controlled valves which open or close by means of an electric current through a solenoid (coil). As long as they are electrically energized they consume energy. They open and close quickly. They are sensitive to dirt and can only be used with clean liquids or gases.

Important

  • Use clean liquids or gases. Solenoid valves are very sensitive to dirt.
  • Do not power the coil when the coil is removed from the valve. The coil will overheat and may burn out.
  • Indirect operated valves need a differential pressure to operate. A closed system, such as a central heating system, generally has an unknown and probably too low differential pressure.
  • Make sure that the valve is suitable for the application and that the materials are suitable for the medium and temperature.

Descriptions

TermDescription
Solenoid ValveElectromechanically operated valve. An electric current through a solenoid is used to open or close the valve.
Indirect operatedIndirect or servo operated solenoid valves use the differential pressure of the medium to open or close the valve. The minimum differential pressure is usually 0.5 bar. Since the fluid pressure is used, a relatively small coil can operate a large diaphragm and thus a high flow.
2/2-Way2 ports (inlet and outlet) and 2 positions (open and closed).
Normally closedThe valve opens when the coil is energized (Normally Closed or NC).
NBRNBR (nitrile rubber) is used for the seal material. Suitable for air, water and oils. NBR is unsuitable for ozone or acetone. EPDM is preferable hot water, steam and alkaline substances. For most other media FKM (Viton) is a more resistant and durable alternative. View the Valve Sizing Calculator.
3/8 inchG3/8 inch pipe thread (BSPP). Determine the valve size based on the desired flow rate and pipe diameter. Using the range of fittings, you can connect the valve to the desired type of pipe.
ValvePipe ⌀
1/8 inch± 4 - 8 mm
1/4 inch± 6 - 12 mm
3/8 inch± 8 - 15 mm
1/2 inch± 10 - 16 mm
3/4 inch± 15 - 22 mm
1 inch± 20 - 30 mm
1½ inch± 25 - 50 mm