electric actuators (ISO 5211)

Electrical actuator with ISO-5211 flange to control ball valves or butterfly valves (0 to 90 degrees or quarter turn rotary control). We offer actuators that can operate with voltages from 12 - 240V AC/DC. Depending on actuator size and AC/DC,... Read more Read more

Product Brand Voltage Material Control signal Nominal power (VA) Width (mm) Manual override Principle of operation safety function ISO 5211 Flange type Degree of protection (IP) ISO 5211 Square head size (mm) Position feedback Max. angle of rotation (°) Operating time (s) Torque (Nm) End contacts Suitable for air accessory Height (mm) With safety function Max. electric power input (VA) Suitable for valve ISO 5211 Direct Mount top flange Model Ambient temperature (°C) Type of safety function Explosion-proof Regulation type modulating With mechanical setting indicator Regulation type splitrange Deactivated when closed Adjustable operating range Potential free switch contact Transmission Regulation type on/off Duty cycle
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) Three-point (open-close) 22.2 110 Yes Fail-safe (NO / NC, depends... Flange F03, Flange F04,... IP67 9 None 90 10 20 2 No 171 Yes 39.6 Yes Yes Rotating -20 °C to 70 °C Electronic No No Yes No No Yes Yes With cogwheels Yes 75%
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) Three-point (open-close) 21.1 110 Yes Fail-safe (NO / NC, depends... Flange F05, Flange F07 IP67 14 None 90 15 55 2 No 196 Yes 48 Yes Yes Rotating -20 °C to 70 °C Electronic No No Yes No No Yes Yes With cogwheels Yes 75%
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) Three-point (open-close) 18.5 110 Yes Fail-safe (NO / NC, depends... Flange F05, Flange F07 IP67 17 None 90 29 85 2 No 196 Yes 38 Yes Yes Rotating -20 °C to 70 °C Electronic No No Yes No No Yes Yes With cogwheels Yes 75%
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 22.2 110 Yes - Flange F03, Flange F04,... IP67 14 4-20 mA, Open & close limit... 90 10 20 2 No 171 No 39.6 Yes Yes Rotating -20 °C to 70 °C - No Yes Yes No No Yes Yes With cogwheels No 75%
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 21.1 110 Yes - Flange F05, Flange F07 IP67 14 4-20 mA, Open & close limit... 90 15 55 2 No 196 No 48 Yes Yes Rotating -20 °C to 70 °C - No Yes Yes No No Yes Yes With cogwheels No 75%
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 21.1 110 Yes - Flange F05, Flange F07 IP67 17 4-20 mA, Open & close limit... 90 15 55 2 No 196 No 48 Yes Yes Rotating -20 °C to 70 °C - No Yes Yes No No Yes Yes With cogwheels No 75%
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 22.2 110 Yes Fail-safe (NO / NC, depends... Flange F03, Flange F04,... IP67 9 4-20 mA, Open & close limit... 90 10 20 2 No 171 Yes 39.6 Yes Yes Rotating -20 °C to 70 °C Electronic No Yes Yes No No Yes Yes With cogwheels No 75%
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 21.1 110 Yes Fail-safe (NO / NC, depends... Flange F05, Flange F07 IP67 14 4-20 mA, Open & close limit... 90 15 55 2 No 196 Yes 48 Yes Yes Rotating -20 °C to 70 °C Electronic No Yes Yes No No Yes Yes With cogwheels No 75%
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 21.1 110 Yes Fail-safe (NO / NC, depends... Flange F05, Flange F07 IP67 17 4-20 mA, Open & close limit... 90 15 55 2 No 196 Yes 48 Yes Yes Rotating -20 °C to 70 °C Electronic No Yes Yes No No Yes Yes With cogwheels No 75%
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 21.1 110 Yes Fail-safe (NO / NC, depends... Flange F05, Flange F07 IP67 17 4-20 mA, Open & close limit... 90 15 55 2 No 196 Yes 48 Yes Yes Rotating -20 °C to 70 °C Electronic No Yes Yes No No Yes Yes With cogwheels No 75%
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) Three-point (open-close) 22.2 110 Yes Fail-safe (NO / NC, depends... Flange F03, Flange F04,... IP67 9 None 90 10 20 2 No 171 Yes 39.6 Yes Yes Rotating -20 °C to 70 °C Electronic No No Yes No No Yes Yes With cogwheels Yes 75%
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) Three-point (open-close) 22.7 110 Yes Fail-safe (NO / NC, depends... Flange F03, Flange F04,... IP67 14 None 90 10 35 2 No 171 Yes 45.9 Yes Yes Rotating -20 °C to 70 °C Electronic No No Yes No No Yes Yes With cogwheels Yes 75%
J3C Modulating 85-240V...
+9 days
J + J 120 V AC, 230 V AC Polyamide (PA) 4-20 mA (modulating) - 214 Yes - Flange F07, Flange F10 IP67 22 4-20 mA, Open & close limit... 90 58 140 2 No 254 No 68.2 Yes Yes Rotating -20 °C to 70 °C - No Yes Yes No No Yes Yes With cogwheels No 75%
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 22.7 110 Yes - Flange F03, Flange F04,... IP67 11 4-20 mA, Open & close limit... 90 10 35 2 No 171 No 45.9 Yes Yes Rotating -20 °C to 70 °C - No Yes Yes No No Yes Yes With cogwheels No 75%
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 18.5 110 Yes - Flange F05, Flange F07 IP67 17 4-20 mA, Open & close limit... 90 29 85 2 No 196 No 38 Yes Yes Rotating -20 °C to 70 °C - No Yes Yes No No Yes Yes With cogwheels No 75%
electric actuators (ISO 5211)

electric actuators (ISO 5211)

Electrical actuator with ISO-5211 flange to control ball valves or butterfly valves (0 to 90 degrees or quarter turn rotary control). We offer actuators that can operate with voltages from 12 - 240V AC/DC. Depending on actuator size and AC/DC, they can deliver from 20 - 300 Nm. The valve position can be clearly seen through the dome indicator and it has a manual override is an option. Actuator options for modulation DPS (Digital Positioning System) or fail-safe BSR (Battery Safety Return) are also available.