electric actuators (ISO 5211)

Electrical actuator with ISO-5211 flange to control ball valves or butterfly valves (0 to 90 degrees or quarter turn rotary control). We offer actuators that can operate with voltages from 12 - 240V AC/DC. Depending on actuator size and AC/DC,... Read more Read more

Product Brand Voltage Material Control signal Width (mm) Manual override Principle of operation safety function ISO 5211 Flange type Degree of protection (IP) ISO 5211 Square head size (mm) Position feedback Max. angle of rotation (°) Operating time (s) Torque (Nm) End contacts Suitable for air accessory Height (mm) With safety function Suitable for valve ISO 5211 Direct Mount top flange Max. electric power input (VA) Model Ambient temperature (°C) Type of safety function Explosion-proof Regulation type modulating Regulation type splitrange With mechanical setting indicator Deactivated when closed Adjustable operating range Potential free switch contact Transmission Duty cycle Regulation type on/off Nominal power (VA)
J3C Modulating Fail-Safe...
+9 days
J + J 120 V AC, 230 V AC Polyamide (PA) 4-20 mA (modulating) 214 Yes Fail-safe (NO / NC, depends... Flange F07, Flange F10 IP67 22 4-20 mA, Open & close limit... 90 58 300 2 No 254 Yes Yes Yes 79.4 Rotating -20 °C to 70 °C Electronic No Yes No Yes No Yes Yes With cogwheels 75% No -
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 110 Yes Fail-safe (NO / NC, depends... Flange F03, Flange F04,... IP67 14 4-20 mA, Open & close limit... 90 10 20 2 No 171 Yes Yes Yes 39.6 Rotating -20 °C to 70 °C Electronic No Yes No Yes No Yes Yes With cogwheels 75% No 22.2
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 110 Yes Fail-safe (NO / NC, depends... Flange F03, Flange F04,... IP67 11 4-20 mA, Open & close limit... 90 10 35 2 No 171 Yes Yes Yes 45.9 Rotating -20 °C to 70 °C Electronic No Yes No Yes No Yes Yes With cogwheels 75% No 22.7
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 110 Yes Fail-safe (NO / NC, depends... Flange F03, Flange F04,... IP67 14 4-20 mA, Open & close limit... 90 10 35 2 No 171 Yes Yes Yes 45.9 Rotating -20 °C to 70 °C Electronic No Yes No Yes No Yes Yes With cogwheels 75% No 22.7
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) Three-point (open-close) 110 Yes Fail-safe (NO / NC, depends... Flange F03, Flange F04,... IP67 14 None 90 10 20 2 No 171 Yes Yes Yes 39.6 Rotating -20 °C to 70 °C Electronic No No No Yes No Yes Yes With cogwheels 75% Yes 22.2
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) Three-point (open-close) 110 Yes Fail-safe (NO / NC, depends... Flange F05, Flange F07 IP67 14 None 90 15 55 2 No 196 Yes Yes Yes 48 Rotating -20 °C to 70 °C Electronic No No No Yes No Yes Yes With cogwheels 75% Yes 21.1
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 110 Yes - Flange F03, Flange F04,... IP67 9 4-20 mA, Open & close limit... 90 10 20 2 No 171 No Yes Yes 39.6 Rotating -20 °C to 70 °C - No Yes No Yes No Yes Yes With cogwheels 75% No 22.2
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 110 Yes - Flange F03, Flange F04,... IP67 9 4-20 mA, Open & close limit... 90 10 20 2 No 171 No Yes Yes 39.6 Rotating -20 °C to 70 °C - No Yes No Yes No Yes Yes With cogwheels 75% No 22.2
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 110 Yes - Flange F03, Flange F04,... IP67 14 4-20 mA, Open & close limit... 90 10 35 2 No 171 No Yes Yes 45.9 Rotating -20 °C to 70 °C - No Yes No Yes No Yes Yes With cogwheels 75% No 22.7
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 110 Yes - Flange F05, Flange F07 IP67 17 4-20 mA, Open & close limit... 90 15 55 2 No 196 No Yes Yes 48 Rotating -20 °C to 70 °C - No Yes No Yes No Yes Yes With cogwheels 75% No 21.1
J3C Fail-Safe 85-240V AC/DC...
+9 days
J + J 120 V AC, 230 V AC Polyamide (PA) Three-point (open-close) 214 Yes Fail-safe (NO / NC, depends... Flange F07, Flange F10 IP67 22 None 90 58 300 2 No 254 Yes Yes Yes 79.4 Rotating -20 °C to 70 °C Electronic No No No Yes No Yes Yes With cogwheels 75% Yes -
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) Three-point (open-close) 110 Yes Fail-safe (NO / NC, depends... Flange F05, Flange F07 IP67 17 None 90 15 55 2 No 196 Yes Yes Yes 48 Rotating -20 °C to 70 °C Electronic No No No Yes No Yes Yes With cogwheels 75% Yes 21.1
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 110 Yes Fail-safe (NO / NC, depends... Flange F03, Flange F04,... IP67 11 4-20 mA, Open & close limit... 90 10 20 2 No 171 Yes Yes Yes 39.6 Rotating -20 °C to 70 °C Electronic No Yes No Yes No Yes Yes With cogwheels 75% No 22.2
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) 110 Yes Fail-safe (NO / NC, depends... Flange F05, Flange F07 IP67 17 4-20 mA, Open & close limit... 90 29 85 2 No 196 Yes Yes Yes 38 Rotating -20 °C to 70 °C Electronic No Yes No Yes No Yes Yes With cogwheels 75% No 18.5
J3C Fail-Safe 85-240V AC/DC...
+9 days
J + J 120 V AC, 230 V AC Polyamide (PA) Three-point (open-close) 214 Yes Fail-safe (NO / NC, depends... Flange F07, Flange F10 IP67 22 None 90 58 140 2 No 254 Yes Yes Yes 68.2 Rotating -20 °C to 70 °C Electronic No No No Yes No Yes Yes With cogwheels 75% Yes -
electric actuators (ISO 5211)

electric actuators (ISO 5211)

Electrical actuator with ISO-5211 flange to control ball valves or butterfly valves (0 to 90 degrees or quarter turn rotary control). We offer actuators that can operate with voltages from 12 - 240V AC/DC. Depending on actuator size and AC/DC, they can deliver from 20 - 300 Nm. The valve position can be clearly seen through the dome indicator and it has a manual override is an option. Actuator options for modulation DPS (Digital Positioning System) or fail-safe BSR (Battery Safety Return) are also available.