Solenoid Valve G1/2'' NC Stainless Steel NBR 0.2-16bar/3-232psi 230VAC Oxygen Fat/Oil Free 5282 462881

Solenoid Valve G1/2'' NC Stainless Steel NBR 0.2-16bar/3-232psi 230VAC Oxygen Fat/Oil Free 5282 462881
Solenoid Valve G1/2'' NC Stainless Steel NBR 0.2-16bar/3-232psi 230VAC Oxygen Fat/Oil Free 5282 462881
Reference: 462881
Brand: Burkert

Burkert 2/2 way solenoid valve (type 5282) with G 1/2 inch threads and a 230 V AC coil. The valve can be set to normally closed (default setting) or normally open. The valve is indirect operating, so a small differential pressure required. Suitable for slightly contaminated and aggressive media (media separation). Suitable for max media temperatures of 80 °C (176 °F) and a pressure range of 0.2 to 16 bar (3 to 232 psi). Housing of stainless steel with NBR sealing and a 20 mm orifice. The Kv-value is 5 m3/h (83.35 l/min at dp = 1 bar water). Manual override feature. The valve is fat and oil free.
Note: DIN connector not included.

View all
Note: product cannot be returned
Regular price
$1007.46
excl VAT

In stock +45 days On request On request
0 are currently in your cart. For orders exceeding 0, expect an increased lead time of 45 days. Up to 1 items available for online order. For higher quantities, please contact us on support@tameson.com to request the lead time. The item is not available for online order, please contact us on support@tameson.com to request the lead time.


Shipping to United States: Free
Free for orders > $390.00
Expected delivery in 47 - 48 business days

Description
Specifications
Downloads
Related products

This is a Burkert indirect operating 2/2 way solenoid valve with G 1/2 inch threads and a 230 V AC coil. The valve has a stainless steel housing with NBR sealing and an orifice size of 20 mm. The circuit function of the solenoid valve is normally closed, which means the valve opens when voltage is applied. However, the function can easily be changed between NC and NO by rotating the pilot valve on the top side by 180 degrees. Suitable for a pressure range of 0.2 to 16 bar (3 to 232 psi) and a maximum temperature of 80 °C (176 °F). The valve has a Kv-value of 5 m3/h, this translates to a flow rate of 83 l/min at a differential pressure of 1 bar (for water). In imperial units: Cv = 6, which means 6 GPM @ 1 psi pressure drop. For many applications it is enough to select a valve based on the thread size and orifice diameter. For more accurate sizing, use the Kv-value with our easy to use valve sizing calculator. This model is media separated. This means that the working parts such as the spring are separated from the media by a flexible membrane, which makes it possible to use of slightly contaminated and aggressive media. The stainless steel housing is very durable, strong and resistant to a wide range of chemicals with the exception of chloride solutions. The NBR (nitrile rubber) sealing is suited for water, air, alcohol and is fairly resistance to oil and petrol. NBR is unsatisfactory with oxidising fluids. Please note that the internal valve parts, such as the stainless steel plunger and springs, are also in contact with the medium and must be chemically compatible. Consult our chemical resistance chart to verify compatibility of housing and seals with the medium. The manual override feature can be used to commission the system. The valve is fat and oil free, meaning it won't contaminate the media. Therefore, it's suitable for laboratory use as well as oxygen. The valve is CSA certified (Class 3221001). This valve is certified to comply with UR Component standard. The valve has an IP65 rating if properly connected.

Pros:

  • Oil and fat free, so the valve does not contaminate the medium
  • The manual override is ideal for commissioning and in case of power outage
  • Good protection against the environment thanks to the IP65 rating
  • Silicone free, so the valve does not contaminate the medium
  • Diaphragm designed to separate aggressive and contaminated media

Cons:

  • Not suited for low pressure differentials (< 0.2 bar). In case of low pressure or a vacuum, consider a (semi-)direct solenoid valve
  • The coil may get hot when energized. A well ventilated environment is recommended
  • DIN connector not included

Series:

The Bürkert 5282 solenoid valve is used for the most demanding applications. The valve is built to last. The media separation makes the 5282 also suitable for aggressive media. The valve is equipped with standard features such as a manual override and adjustable opening and closing times. Furthermore, the circuit function can easily be changed from NC to NO, by simply rotating the 3/2 way pilot valve on top of the main valve body. The 5282 valve is available with a wide variation of housing and sealing materials. The brass housing satisfies all European drinking water requirements. Various ATEX versions are available for potentially explosive environment.