We use cookies and related techniques to improve your experience. We collect, share and use personal data for the personalization of ads. By using the website you agree to the use of cookies.
Product | Brand | Connection size | Thread size | Material | Contacts | Seal material | Suitable for oil | Max switch capacity | Switch hysteresis | Electrical connection | Min pressure (bar) | Max pressure (bar) | Max. overpressure (bar) | Connection type | Pressure sensor feature | Degree of protection (IP) | Min temperature (°C) | Max temperature (°C) | Suitable for gases | Measuring element |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() -0.98 to -0.2bar SPDT Brass Vacuum Switch G1/8'' 42VAC...PSL-B-N-0P98-0P2-OC-FP-V
+2 days
|
Tameson | 1/8 inch | 1/8 inch | Brass | Changeover contact | NBR (nitrile rubber) | Yes | 5 A / 30 V DC, 5 A / 42 V AC | 15 - 25 percent | Flat plug-in connection | -0.98 | -0.2 | 2 | Outer thread cylindrical... | For vacuum | IP65 | -25 | 85 | No | Membrane |
![]() -0.95 to -0.2bar NO Brass Vacuum Switch G1/8'' 42VAC/DC...0151-45215-3-001
+2 days
|
SUCO | 1/8 inch | 1/8 inch | Brass | Normally open | FKM (FPM) | Yes | 100 VA / 42 V AC/DC | 5 - 15 percent | Screw terminal | -0.95 | -0.2 | 20 | Inner thread cylindrical... | For vacuum | IP65 | -5 | 120 | No | Membrane |
![]() -0.98 to -0.2bar SPDT Aluminium Vacuum Switch G1/4''...PSL-A-N-0P98-0P2-OC-TA-V
+2 days
|
Tameson | 1/4 inch | 1/4 inch | Aluminium | Changeover contact | NBR (nitrile rubber) | Yes | 5 A / 30 V DC, 5 A / 250 V AC | 15 - 25 percent | DIN-A | -0.98 | -0.2 | 2 | Inner thread cylindrical... | Can be turned 360 deg, For... | IP65 | -25 | 85 | No | Membrane |
![]()
$85.27
+2 days
|
Barcontrol | 1/4 inch | 1/4 inch | Zinc die-cast | Changeover contact | NBR (nitrile rubber) | Yes | 3 A / 24 V DC, 6 A / 250 V AC | 100 - 250 mbar | DIN-A | -0.85 | -0.15 | 20 | Inner thread cylindrical... | For vacuum, With adjustment... | IP65 | -20 | 80 | No | Membrane |
![]()
$85.27
+2 days
|
Barcontrol | - | - | Zinc die-cast | Changeover contact | NBR (nitrile rubber) | Yes | 3 A / 24 V DC, 6 A / 250 V AC | 100 - 250 mbar | DIN-A | -0.85 | -0.15 | 20 | Flange 5.3x20 | For vacuum, With adjustment... | IP65 | -20 | 80 | No | Membrane |
![]()
$89.16
+2 days
|
Barcontrol | - | - | Zinc die-cast | Changeover contact | NBR (nitrile rubber) | Yes | 3 A / 24 V DC, 6 A / 250 V AC | 100 - 250 mbar | Plug-in connection M12 | -0.85 | -0.15 | 20 | Flange 5.3x20 | For vacuum, With adjustment... | IP67 | -20 | 80 | No | Membrane |
![]() -0.95 to -0.1bar SPDT Aluminium Vacuum Switch G1/8''...0150-45615-4-001
+2 days
|
SUCO | 1/8 inch | 1/8 inch | Aluminium | Changeover contact | ECO | Yes | 3.5 A / 30 V DC, 3.5 A /... | 10 - 30 percent | DIN-A | -0.95 | -0.1 | 20 | Inner thread cylindrical... | For vacuum | IP65 | -20 | 100 | No | Membrane |
![]() -0.95 to -0.2bar NC Brass Vacuum Switch G1/8'' 42VAC/DC...0151-45315-3-001
+2 days
|
SUCO | 1/8 inch | 1/8 inch | Brass | Normally closed | FKM (FPM) | Yes | 100 VA / 42 V AC/DC | 5 - 15 percent | Screw terminal | -0.95 | -0.2 | 20 | Inner thread cylindrical... | For vacuum | IP65 | -5 | 120 | No | Membrane |
Vacuum switches operate an electrical contact when a certain fluid pressure has been reached. When the pressure reaches the set-point or reset-point the pressure switch opens or closes the contacts to prevent under- or overpressure of a system.
Tameson provides two main types of vacuum switches: electromechanical and mechanical (solid state). The mechanical vacuum switches are available with three different types of contacts: normally open (NO), normally closed (NC) and changeover (Single Pole, Double Throw or SPDT). The electronic vacuum switches have a digital display to set up the switching function. In a pressure switch, a diaphragm or a piston opens or closes a circuit when the pressure reaches the set-point or drops to a reset-point. In the mechanical vacuum switch, the setting pressure is typically adjusted with a hex key or turning knob. In the electrical vacuum switch the set-point and reset-point can be adjusted with a digital display. The difference between the switch point and the reset point is hysteresis. Hysteresis for mechanical vacuum switches is usually determined by the manufacturer, the hysteresis for electronic pressure vacuum is usually configurable.
Our vacuum switches are available with different types of housing material and seal. The media and temperature range are important to choose the material. Check our chemical resistance table to choose the correct material.
Other important factors to select a vacuum switch are: maximum overpressure, degree of ingress protection, ATEX approvals, reproducibility, resistance to vibration and shock, process connections, switch capacity and the type of electrical connection.
This wizard allows you to filter the most important features for this product category. Please select the options that are essential for your application, it is not required to select options for each feature. The amount of results is automatically updated and shown on the bottom.
Select country