compressor pressure switches

A compressor pressure switch is used to control compressors, tanks or similar closed systems. Our compressor pressure switches are suitable for water and air. Therefore, their application is not limited to compressors. They’re also popular to... Read more Read more

Product Brand Connection size Thread size Material Seal material Contacts Suitable for oil Max switch capacity Electrical connection Max pressure (bar) Connection type Pressure sensor feature Max temperature (°C) Min temperature (°C) Degree of protection (IP) Min pressure (bar) Suitable for gases Measuring element
2 to 11bar Compressor...
In stock
Cóndor 1/2 inch 1/2 inch Aluminium die-cast NBR (nitrile rubber) Normally closed No 4 kW / 230 V AC, 5.5 kW /... Cable clamp 11 Inner thread cylindrical... 3-phase AC, Push-button 80 -5 IP54 2 No Membrane
6 to 16bar Compressor...
In stock
Cóndor 1/2 inch 1/2 inch Aluminium die-cast CR (neoprene) Changeover contact No 0.55 kW / 230 V AC Cable clamp 16 Inner thread cylindrical... No manual switch 80 -30 IP54 6 No Membrane
0.5 to 8bar Compressor...
+2 days
Cóndor 1/2 inch 1/2 inch Aluminium die-cast CR (neoprene) Changeover contact No 0.55 kW / 230 V AC Cable clamp 8 Inner thread cylindrical... No manual switch 80 -30 IP54 0.5 No Membrane
4 to 11bar Compressor...
+2 days
Cóndor 1/2 inch, 1/4 inch 1/2 inch Aluminium die-cast NBR (nitrile rubber) Normally closed No 3.0 kW / 120 V AC, 5.5 kW /... Cable clamp 11 Inner thread cylindrical... 3-phase AC, Rotary lever 80 -5 IP54 4 No Membrane
4 to 12bar Compressor...
+2 days
Cóndor 1/4 inch 1/4 inch Aluminium die-cast SBR/NBR Normally closed No 1.1 kW / 120 V AC, 2.2 kW /... Cable clamp 12 Inner thread cylindrical... 1-phase AC, Rotary lever 80 -5 IP44 4 No Membrane
2.5 to 16bar Compressor...
+2 days
Cóndor 1/2 inch 1/2 inch Aluminium die-cast NBR (nitrile rubber) Normally closed No 4 kW / 230 V AC, 5.5 kW /... Cable clamp 16 Inner thread cylindrical... 3-phase AC, Push-button 80 -5 IP54 2.5 No Membrane
2.5 to 16bar Compressor...
+2 days
Cóndor 1/2 inch 1/2 inch Aluminium die-cast NBR (nitrile rubber) Normally closed No 4 kW / 230 V AC, 5.5 kW /... Cable clamp 16 Inner thread cylindrical... 3-phase AC, No manual switch 80 -5 IP54 2.5 No Membrane
4 to 11bar Compressor...
+2 days
Cóndor 1/2 inch, 1/4 inch 1/2 inch Aluminium die-cast SBR/NBR Normally closed No 4 kW / 230 V AC, 5.5 kW /... Cable clamp 11 Inner thread cylindrical... 3-phase AC, Rotary lever 80 -5 IP54 4 No Membrane
2 to 11bar Compressor...
+2 days
Cóndor 1/2 inch 1/2 inch Aluminium die-cast NBR (nitrile rubber) Normally closed No 4 kW / 230 V AC, 5.5 kW /... Cable clamp 11 Inner thread cylindrical... 3-phase AC, No manual switch 80 -5 IP54 2 No Membrane
4 to 12bar Compressor...
+2 days
Cóndor 1/4 inch 1/4 inch Aluminium die-cast SBR/NBR Normally closed No 1.1 kW / 120 V AC, 2.2 kW /... Cable clamp 12 Inner thread cylindrical... 1-phase AC, No manual switch 80 -5 IP44 4 No Membrane
6 to 16bar Compressor...
+2 days
Cóndor 1/2 inch, 1/4 inch 1/2 inch Aluminium die-cast NBR (nitrile rubber) Normally closed No 3.0 kW / 120 V AC, 5.5 kW /... Cable clamp 16 Inner thread cylindrical... 3-phase AC, Rotary lever 80 -5 IP54 6 No Membrane
3 to 10bar Compressor...
+2 days
Cóndor 1/2 inch 1/2 inch Aluminium die-cast NBR (nitrile rubber) Normally closed Yes 3.0 kW / 120 V AC, 5.5 kW /... Cable clamp 10 Inner thread cylindrical... 3-phase AC, Rotary lever 80 -5 IP54 3 Yes Membrane
1 to 6bar Compressor...
+2 days
Cóndor 1/2 inch 1/2 inch Aluminium die-cast NBR (nitrile rubber) Normally closed Yes 3.0 kW / 120 V AC, 5.5 kW /... Cable clamp 6 Inner thread cylindrical... 3-phase AC, No manual switch 80 -5 IP54 1 Yes Membrane
4 to 11bar Compressor...
+2 days
Cóndor 1/2 inch, 1/4 inch 1/2 inch Aluminium die-cast NBR (nitrile rubber) Normally closed No 3.0 kW / 120 V AC, 5.5 kW /... Cable clamp 11 Inner thread cylindrical... 3-phase AC, No manual switch 80 -5 IP54 4 No Membrane
6 to 11bar Compressor...
+2 days
Cóndor 1/2 inch 1/2 inch Aluminium die-cast CR (neoprene) Changeover contact No 0.55 kW / 230 V AC Cable clamp 11 Inner thread cylindrical... No manual switch 80 -30 IP54 6 No Membrane
compressor pressure switches

compressor pressure switches

A compressor pressure switch is used to control compressors, tanks or similar closed systems. Our compressor pressure switches are suitable for water and air. Therefore, their application is not limited to compressors. They’re also popular to control water pumps for instance or to trigger alarms. Furthermore, we also provide versions that can be used with a wide range of other media.

Compressor pressure switches are either normally open (NO), normally closed (NC) or with changeover contacts (SPDT). The switch capacity varies per model. The switches have a cut-in and a cut-out pressure. The difference between cut-in and cut-out pressures is called hysteresis, the pressure band or pressure differential. With most types, you can set the cut-in pressure and the hysteresis. Each switch has a range of cut-in and cut-out pressures that can be visualized in a pressure diagram. When used with a compressor, make sure that the difference between cut-in and cut-out pressure is not too small. This will result in a quick start and stop sequence that will cause excessive wear on the compressor motor and switch. The switches are available with different options: with push button, rotary switch and with a variation in port connections and sizes.