Tameson has partnered with J+J Automation to be a distributor of their electric actuators. J+J Automation is a leading global manufacturer and provider of electric actuators and services. Tameson's full J+J Automation product offering and support is listed below. If you are looking for a J+J Automation product that is not listed below, contact us.

Product Brand Voltage Material Control signal Manual override Operating time (s) Principle of operation safety function ISO 5211 Flange type Degree of protection (IP) Nominal power (VA) ISO 5211 Square head size (mm) Position feedback Torque (Nm) End contacts Width (mm) Suitable for air accessory Max. electric power input (VA) Duty cycle With safety function Suitable for valve ISO 5211 Direct Mount top flange Type of safety function Height (mm) Model Explosion-proof Regulation type modulating With mechanical setting indicator Ambient temperature (°C) Regulation type splitrange Deactivated when closed Transmission Adjustable operating range Potential free switch contact Degree of protection (NEMA) Regulation type on/off Max. angle of rotation (°)
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) Three-point (open-close) Yes 10 Fail-safe (NO / NC, depends... Flange F03, Flange F04,... IP67 22.7 11 None 35 2 110 No 45.9 75% Yes Yes Yes Electronic 171 Rotating No No Yes -20 °C to 70 °C No No With cogwheels Yes Yes 0 Yes 90
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) Three-point (open-close) Yes 15 Fail-safe (NO / NC, depends... Flange F05, Flange F07 IP67 21.1 17 None 55 2 110 No 48 75% Yes Yes Yes Electronic 196 Rotating No No Yes -20 °C to 70 °C No No With cogwheels Yes Yes 0 Yes 90
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) Three-point (open-close) Yes 10 Fail-safe (NO / NC, depends... Flange F03, Flange F04,... IP67 22.2 11 None 20 2 110 No 39.6 75% Yes Yes Yes Electronic 171 Rotating No No Yes -20 °C to 70 °C No No With cogwheels Yes Yes 0 Yes 90
J3C Modulating 85-240V...
+9 days
J + J 120 V AC, 230 V AC Polyamide (PA) 4-20 mA (modulating) Yes 58 - Flange F07, Flange F10 IP67 - 22 4-20 mA, Open & close limit... 300 2 214 No 79.4 75% No Yes Yes - 254 Rotating No Yes Yes -20 °C to 70 °C No No With cogwheels Yes Yes 0 No 90
J3C Modulating Fail-Safe...
+9 days
J + J 120 V AC, 230 V AC Polyamide (PA) 4-20 mA (modulating) Yes 58 Fail-safe (NO / NC, depends... Flange F07, Flange F10 IP67 - 22 4-20 mA, Open & close limit... 140 2 214 No 68.2 75% Yes Yes Yes Electronic 254 Rotating No Yes Yes -20 °C to 70 °C No No With cogwheels Yes Yes 0 No 90
J3C Modulating Fail-Safe...
+9 days
J + J 120 V AC, 230 V AC Polyamide (PA) 4-20 mA (modulating) Yes 58 Fail-safe (NO / NC, depends... Flange F07, Flange F10 IP67 - 22 4-20 mA, Open & close limit... 300 2 214 No 79.4 75% Yes Yes Yes Electronic 254 Rotating No Yes Yes -20 °C to 70 °C No No With cogwheels Yes Yes 0 No 90
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) Yes 10 Fail-safe (NO / NC, depends... Flange F03, Flange F04,... IP67 22.2 14 4-20 mA, Open & close limit... 20 2 110 No 39.6 75% Yes Yes Yes Electronic 171 Rotating No Yes Yes -20 °C to 70 °C No No With cogwheels Yes Yes 0 No 90
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) Yes 10 Fail-safe (NO / NC, depends... Flange F03, Flange F04,... IP67 22.7 11 4-20 mA, Open & close limit... 35 2 110 No 45.9 75% Yes Yes Yes Electronic 171 Rotating No Yes Yes -20 °C to 70 °C No No With cogwheels Yes Yes 0 No 90
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) Yes 10 Fail-safe (NO / NC, depends... Flange F03, Flange F04,... IP67 22.7 14 4-20 mA, Open & close limit... 35 2 110 No 45.9 75% Yes Yes Yes Electronic 171 Rotating No Yes Yes -20 °C to 70 °C No No With cogwheels Yes Yes 0 No 90
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) Three-point (open-close) Yes 10 Fail-safe (NO / NC, depends... Flange F03, Flange F04,... IP67 22.2 14 None 20 2 110 No 39.6 75% Yes Yes Yes Electronic 171 Rotating No No Yes -20 °C to 70 °C No No With cogwheels Yes Yes 0 Yes 90
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) Three-point (open-close) Yes 15 Fail-safe (NO / NC, depends... Flange F05, Flange F07 IP67 21.1 14 None 55 2 110 No 48 75% Yes Yes Yes Electronic 196 Rotating No No Yes -20 °C to 70 °C No No With cogwheels Yes Yes 0 Yes 90
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) Yes 10 - Flange F03, Flange F04,... IP67 22.2 9 4-20 mA, Open & close limit... 20 2 110 No 39.6 75% No Yes Yes - 171 Rotating No Yes Yes -20 °C to 70 °C No No With cogwheels Yes Yes 0 No 90
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) Yes 10 - Flange F03, Flange F04,... IP67 22.2 9 4-20 mA, Open & close limit... 20 2 110 No 39.6 75% No Yes Yes - 171 Rotating No Yes Yes -20 °C to 70 °C No No With cogwheels Yes Yes 0 No 90
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) Yes 10 - Flange F03, Flange F04,... IP67 22.7 14 4-20 mA, Open & close limit... 35 2 110 No 45.9 75% No Yes Yes - 171 Rotating No Yes Yes -20 °C to 70 °C No No With cogwheels Yes Yes 0 No 90
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 4-20 mA (modulating) Yes 15 - Flange F05, Flange F07 IP67 21.1 14 4-20 mA, Open & close limit... 55 2 110 No 48 75% No Yes Yes - 196 Rotating No Yes Yes -20 °C to 70 °C No No With cogwheels Yes Yes 0 No 90