Tameson has partnered with J+J Automation to be a distributor of their electric actuators. J+J Automation is a leading global manufacturer and provider of electric actuators and services. Tameson's full J+J Automation product offering and support is listed below. If you are looking for a J+J Automation product that is not listed below, contact us.

Product Brand Voltage Material Operating time (s) Principle of operation safety function Manual override Torque (Nm) ISO 5211 Flange type ISO 5211 Square head size (mm) Position feedback End contacts Height (mm) Suitable for air accessory Width (mm) Max. electric power input (VA) Ambient temperature (°C) With safety function Suitable for valve ISO 5211 Direct Mount top flange Type of safety function Adjustable operating range Degree of protection (IP) Control signal Model Nominal power (VA) Explosion-proof Regulation type modulating With mechanical setting indicator Regulation type splitrange Deactivated when closed Transmission Potential free switch contact Duty cycle Degree of protection (NEMA) Regulation type on/off Max. angle of rotation (°)
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 10 Fail-safe (NO / NC, depends... Yes 35 Flange F03, Flange F04,... 11 None 2 171 No 110 45.9 -20 °C to 70 °C Yes Yes Yes Electronic Yes IP67 Three-point (open-close) Rotating 22.7 No No Yes No No With cogwheels Yes 75% 0 Yes 90
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 15 Fail-safe (NO / NC, depends... Yes 55 Flange F05, Flange F07 17 None 2 196 No 110 48 -20 °C to 70 °C Yes Yes Yes Electronic Yes IP67 Three-point (open-close) Rotating 21.1 No No Yes No No With cogwheels Yes 75% 0 Yes 90
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 10 Fail-safe (NO / NC, depends... Yes 20 Flange F03, Flange F04,... 11 None 2 171 No 110 39.6 -20 °C to 70 °C Yes Yes Yes Electronic Yes IP67 Three-point (open-close) Rotating 22.2 No No Yes No No With cogwheels Yes 75% 0 Yes 90
J3C Modulating 85-240V...
+9 days
J + J 120 V AC, 230 V AC Polyamide (PA) 58 - Yes 300 Flange F07, Flange F10 22 4-20 mA, Open & close limit... 2 254 No 214 79.4 -20 °C to 70 °C No Yes Yes - Yes IP67 4-20 mA (modulating) Rotating - No Yes Yes No No With cogwheels Yes 75% 0 No 90
J3C Modulating Fail-Safe...
+9 days
J + J 120 V AC, 230 V AC Polyamide (PA) 58 Fail-safe (NO / NC, depends... Yes 140 Flange F07, Flange F10 22 4-20 mA, Open & close limit... 2 254 No 214 68.2 -20 °C to 70 °C Yes Yes Yes Electronic Yes IP67 4-20 mA (modulating) Rotating - No Yes Yes No No With cogwheels Yes 75% 0 No 90
J3C Modulating Fail-Safe...
+9 days
J + J 120 V AC, 230 V AC Polyamide (PA) 58 Fail-safe (NO / NC, depends... Yes 300 Flange F07, Flange F10 22 4-20 mA, Open & close limit... 2 254 No 214 79.4 -20 °C to 70 °C Yes Yes Yes Electronic Yes IP67 4-20 mA (modulating) Rotating - No Yes Yes No No With cogwheels Yes 75% 0 No 90
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 10 Fail-safe (NO / NC, depends... Yes 20 Flange F03, Flange F04,... 14 4-20 mA, Open & close limit... 2 171 No 110 39.6 -20 °C to 70 °C Yes Yes Yes Electronic Yes IP67 4-20 mA (modulating) Rotating 22.2 No Yes Yes No No With cogwheels Yes 75% 0 No 90
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 10 Fail-safe (NO / NC, depends... Yes 35 Flange F03, Flange F04,... 11 4-20 mA, Open & close limit... 2 171 No 110 45.9 -20 °C to 70 °C Yes Yes Yes Electronic Yes IP67 4-20 mA (modulating) Rotating 22.7 No Yes Yes No No With cogwheels Yes 75% 0 No 90
J3C Modulating Fail-Safe...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 10 Fail-safe (NO / NC, depends... Yes 35 Flange F03, Flange F04,... 14 4-20 mA, Open & close limit... 2 171 No 110 45.9 -20 °C to 70 °C Yes Yes Yes Electronic Yes IP67 4-20 mA (modulating) Rotating 22.7 No Yes Yes No No With cogwheels Yes 75% 0 No 90
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 10 Fail-safe (NO / NC, depends... Yes 20 Flange F03, Flange F04,... 14 None 2 171 No 110 39.6 -20 °C to 70 °C Yes Yes Yes Electronic Yes IP67 Three-point (open-close) Rotating 22.2 No No Yes No No With cogwheels Yes 75% 0 Yes 90
J3C Fail-Safe 24-240V AC/DC...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 15 Fail-safe (NO / NC, depends... Yes 55 Flange F05, Flange F07 14 None 2 196 No 110 48 -20 °C to 70 °C Yes Yes Yes Electronic Yes IP67 Three-point (open-close) Rotating 21.1 No No Yes No No With cogwheels Yes 75% 0 Yes 90
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 10 - Yes 20 Flange F03, Flange F04,... 9 4-20 mA, Open & close limit... 2 171 No 110 39.6 -20 °C to 70 °C No Yes Yes - Yes IP67 4-20 mA (modulating) Rotating 22.2 No Yes Yes No No With cogwheels Yes 75% 0 No 90
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 10 - Yes 20 Flange F03, Flange F04,... 9 4-20 mA, Open & close limit... 2 171 No 110 39.6 -20 °C to 70 °C No Yes Yes - Yes IP67 4-20 mA (modulating) Rotating 22.2 No Yes Yes No No With cogwheels Yes 75% 0 No 90
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 10 - Yes 35 Flange F03, Flange F04,... 14 4-20 mA, Open & close limit... 2 171 No 110 45.9 -20 °C to 70 °C No Yes Yes - Yes IP67 4-20 mA (modulating) Rotating 22.7 No Yes Yes No No With cogwheels Yes 75% 0 No 90
J3C Modulating 24-240V...
+9 days
J + J 24 V AC, 24 V DC, 120 V AC,... Polyamide (PA) 15 - Yes 55 Flange F05, Flange F07 14 4-20 mA, Open & close limit... 2 196 No 110 48 -20 °C to 70 °C No Yes Yes - Yes IP67 4-20 mA (modulating) Rotating 21.1 No Yes Yes No No With cogwheels Yes 75% 0 No 90